Parameter,
measurement unit, measuring mode |
Symbol
letter |
Rated value |
|
not less
than |
not more
than |
|
Low level output voltage, V at I/OL
= 100 mAat I/OL = 500 mA |
U/ol |
- - |
1,2 1,8 |
|
High level output voltage, Vat I/OH =
-100 mA |
U/oh |
8,0 |
- |
|
Blocking input voltage, V for
output 2: U/CC<U/CC E at I/I = 1 mA for output 3: U/CC<U/CC
E at I/I = 1 mA after protection is activated at I/I = 1 mA at I/I = 1
mA at I/I = -1 mA |
U/1k2 U/1k3n U/1k3s U/1k8p U/1k8n |
5,6 5,6 - 0,7 -0,15 |
7,6 7,6 0,8 0,85 -0,25 |
|
Rest input voltage, V for output
2 for output 7 |
U/iq2 U/iq7 |
0,90 2,2 |
1,15 2,9 |
|
Feedback reading voltage, V for output
1 |
U/fb |
0,37 |
0,43 |
|
Release voltage, V for output
3 for output 8 |
U/itn3 U/tn8 |
0.92 0,04 |
1,08 - |
|
Operate voltage, V in the short
circuit, load mode U/I I = 0 V: foroutput 2 in the soft start
mode for output 2 U/I I = U/I7 = 0V |
U/itp2k U/itp2s |
2,2 1,0 |
3,0 1,4 |
|
Input current, mA for output
1 in the short circuit mode at U/I 1 = 0V for output 2 at U/I 2 =
0 VU/I 3 = 4V for output 8 at U/I 8 = 0V |
I/i1 I/i2 I/i8 |
-0,09 -0,40 0 |
-0,18 -0,85 -0,004 |
|
Consumption current, mA before the
integrated circuit is activated (the integrated circuit is off) after the
integrated circuit is activated Zero detector blocking time, mcs |
I/cc I/cce T/ul |
0,5 6,0 2,0 |
1,6 12,0 6,0 |
|