Parameter,
measurement unit, measuring mode |
Symbol
letter |
Rated value |
|
not less
than |
not more
than |
|
Direct current input voltage at output
2, V |
Ui |
4,0 |
4,8 |
|
Output voltage at output 1, V |
Uoh |
3,2 |
5,0 |
|
50/60 Hz detector output voltage at
output 13, V: - low level |
Uol
|
-
|
0,5
|
|
- high level f = 50 Hz f = 60
Hz |
Uoh |
11 7,2 |
- 8,0 |
|
Stabilised voltage at output 16,
V |
U |
8,0 |
9,5 |
|
Frame scan protection circuit
threshold switching levels, V (at output 2) |
Utl Uth |
3,0 4,75 |
3,7 5,55 |
|
Blanking voltage at output 17, V
for horizontal blanking for frame blanking |
Uo |
4,2 2,0
|
5,0 3,0
|
|
Strobe pulse voltage at output 17,
V |
Ustb |
10 |
- |
|
Video signal detector output voltage
at output 18, V when video signal is absent when video signal is
present during operation with video tape recorder |
Uo
|
0 6,5 1,8 |
0,5 8,0 3,4 |
|
Input current, mcA - output 2
- output 12 |
Ii |
- 200 |
2 4000 |
|
Consumption current at output 10,
mA |
Icc |
- |
70 |
|
Delay from the sync pulse leading edge
to the chrominance subcarrier strobe pulse edge (outputs 5, 17) mcs |
Td1 |
4,5 |
5,3 |
|
Delay from the horizontal blanking
pulse edge to the sync pulse front edge (outputs 5, 17) mcs |
Td2 |
0,5 |
2,0 |
|
Chrominance subcarrier strobe pulse
duration at output 17, mcs |
Tw(stb) |
3,6 |
4,4 |
|
Delay from horizontal blanking pulse
cutoff edge (cutoff of reverse pulse to the edge) (outputs 17, 12)
mcs |
Td3 |
- |
0,5 0,7 |
Frame blanking pulse
duration at output 17, line scan periods, mcs F =50 Hz F = 60 Hz |
Tw |
20,5 16,5 |
21,5 17,5 |
|
Delay from reverse pulse cutoff to
line scanning output pulse cutoff at output 11, ms - at tD = 10
mcs - at tD = 1 mcs - at tD = 45 mcs |
Td4 |
- |
0,7 |
|
Horizontal scanning master generator
own frequency, Hz |
F |
15000 |
16250 |
|
Horizontal scanning master generator
generation frequency in the synchronisation mode (lock-on mode), Hz |
F |
15625+/-15 |
15625+/-15 |
|
Horizontal scanning master generator
own frequency in the triggering mode, Hz |
Fg1 |
14375 |
16875 |
|
Vertical scanning master generator own
frequency, Hz |
Fg2 |
44 |
48 |
|
Change of vertical scanning generator
own frequency, if supply voltage changes from 10V to 13V, % |
|
- |
0,2 |
|
Capture range, Hz |
|
+/- 600 |
- |
|
Vertical scanning synchronisation
range, % |
|
30 |
- |
|
Line scanning output signal pulse
ratio without reverse pulse, % In the triggering mode |
K |
45 55 |
55 70 |
Frequency change
temperature factor, K-1: For vertical scanning For horizontal
scanning |
Kt |
- - |
1*10 -4 3*10
-4 |
|
Peak-to-peak amplitude at output 11,
V |
|
7,0 |
- |
|
Line pulse horizontal output stage
protection voltage, V |
Uomax |
13 |
17 |
|
Low level output voltage at output 11,
V |
Uol |
- |
0,5 |
|